# Light steel fabrication and erection checklist

A simplified version of Table 10.1. Tick the items, print them or save as PDF.

## Material check

- Steel grade: Does the steel conform to TS EN 10346 and TS EN ISO 1461?
- Quality certificate: Was the mill test certificate of the steel sheet checked?
- Galvanized coating: Was the coating amount selected according to Annex 1 Table 1?
- Screws and fasteners: Were the requirements of Section 2 met for the screws?
- Holes made on site: Were holes and cuts repaired with zinc-rich paint?

## Cross-section requirements

- Profile dimensions: Do the flange, web and stiffener dimensions meet the limits?
- Bend radii: Do the inner bend radii meet the limits?
- Flange width: Does the flange width meet the minimum limits?

## Conformity to the project

- Profile production: Was the accuracy of the profiles checked against the project?
- Section check: Were shape, dimensions and surface flatness compared with the project?
- Screw check: Do the diameter, position and frequency of the screw holes conform to the project?

## Erection

- Layout: Are the position and alignment of the members correct?
- Connections: Were the specified number and type of screws used?
- Anchor installation: Were the anchors installed at the specified diameter and spacing?
- Connection gussets: Were the gussets fixed with the specified number and size of screws?

## Panel systems

- Sheathing panel layout: Is the stud spacing at most 625 mm and the studs ≥ 0.9 mm?
- Panel frame: Are the top and bottom tracks from profiles ≥ 0.8 mm?
- Screw connections: Were the sheathing panels screwed on all four edges according to the project and TBDY?
- Horizontal bridging: Was the bridging placed at no more than half the panel height?

## Floor system

- Floor joists: Are the joists in the section and spacing required by the project?
- Web reinforcement: Were the stiffeners and connection elements installed in sufficient numbers?
- Floor connections: Were the web and joints connected with screws as required by the project?

## Fire and report

- Fire design: Were the requirements of Section 11 met?
- Design report: Was the calculation report attached?